Main station|Member Center|Save the desktop|Mobile browsing
Ordinary Member

乐清市嘉然防爆照明科技有限公司销售部

LED防爆吸顶灯,LED防爆壁灯,LED防爆管吊灯,LED防爆路灯,LED防爆投光灯,LED防爆泛 ...

sell
  • There is no classification
contact
  • Contact:朱斌
  • Phone:0577-61779168
  • fax:0577-61779166
search
 
link
  • There is no link yet
home > sell > 120w led explosion-proof light for gas station
120w led explosion-proof light for gas station
products: Views:58120w led explosion-proof light for gas station 
brand: 嘉然防爆
price: 面议
MOQ:
Total supply:
Delivery date: Shipped within 3 days from the date of payment by the buyer
Valid until: Long-term validity
Last updated: 2016-04-02 15:03
 
Details
Gas station explosion-proof lights sales in Xinzhou District, Shangrao City, gas station explosion-proof canopy lights supplier in Longlin County, Baise City, Jiayuguan: gas station explosion-proof canopy lights stores in Xiongguan District, Changcheng District, Jingtie District. I just got a call from Kunming, Yunnan. It’s an old customer of mine. He purchased a number of lamps from us a few days ago. The main purpose of his call today is to consult me about the use, installation and technical knowledge of lamps. Below I will Share it with everyone, hope it can help you.
Usage
Users should understand the performance of explosion-proof lamps. If any abnormality is found, they should cut off the power and report for repair. Personnel who are not full-time maintenance personnel are not allowed to perform repairs without authorization.
Users of portable explosion-proof lamps should read the instruction manual in detail, clarify the use location and product performance, and use the lamps in strict accordance with the usage requirements. When the battery is used up, it should be replaced or charged in time. If it is not used for a long time, the battery should be removed to avoid corrosion of the lamp. It is strictly prohibited to open lamps, replace batteries or light sources in explosive hazardous areas.
Maintenance
Explosion-proof lamps should be maintained regularly during use and repaired in time.
Maintenance and repair personnel need to undergo on-the-job training to understand the performance of lamps and clarify usage requirements. Maintenance personnel must have professional knowledge and be familiar with the structure of lighting products.
Regularly eliminate dust and dirt on the housing of explosion-proof lamps to improve the light efficiency and heat dissipation performance of the lamps. The cleaning method can be based on the protective capabilities of the lamp casing, spraying water (the mark on the lamp is negative or above) or wiping with a damp cloth. When spraying water for cleaning, the power supply should be cut off, and it is strictly forbidden to use a dry cloth to wipe the plastic casing (transparent parts) of the lamp to prevent the generation of static electricity.
Check whether the plastic shell (transparent part) of the lamp has serious discoloration. If the discoloration is serious, it means that the plastic has aged. Check whether the transparent parts have any traces of being impacted by foreign objects, and whether the protective net is loose, desoldered, corroded, etc. If so, stop using it and repair and replace it in time.
If the light source is damaged, the lights should be turned off in time and notified of replacement, so as to prevent the ballast and other electrical components from being in an abnormal state for a long time due to the failure of the light source to start.
If there is water accumulation in the lamp cavity of lamps used in humid environments, they should be removed in time and the sealing parts should be replaced to ensure the protective performance of the shell.
When opening the lampshade, follow the instructions on the warning sign, cut off the power supply, and then open the cover.
After opening the cover, you should check whether the flameproof joint surface is intact, whether the rubber seal has become hard or sticky, whether the wire insulation layer is green and carbonized, and whether the insulating parts and electrical components have deformation and scorch marks. If these problems are found, they should be repaired and replaced in time.
The model, specification, size and performance of the light source, parts and electrical components after repair and replacement should be exactly the same as those before repair and replacement.
Before closing the cover, lightly wipe the light return and transparent parts of the lamp with a damp cloth (not too wet) to improve the light efficiency of the lamp. A thin layer of replacement anti-rust oil should be applied to the flameproof joint surface. When closing the cover, attention should be paid to whether the sealing ring plays a sealing role in its original position.
The sealed part of the lamp should not be disassembled and opened frequently.
Yichun Fengcheng gas station explosion-proof lamp 3 manufacturer, Lishui City Songyang County gas station explosion-proof lamp promotion, Qingyuan City Liannan Yao Autonomous County gas station explosion-proof lamp store, Ganzhou City Chongyi County sandblasting room explosion-proof lamp manufacturer.